Malignant Detection of Breast Nodules On BIRADS-Based Ultrasound Images Margin, Orientation, And Posterior

Keywords: Nodule, BIRADS, Margin, Orientation, Posterior

Abstract

Breast cancer has the largest prevalence in the world in 2020, with 2,261,419 cases or 11.7%. It is also the leading cause of cancer death, accounting for 6.9% of all cancer deaths. Asia and Indonesia have the greatest prevalence and mortality rates. This is an urgent issue that must be addressed. Ultrasonography (USG) is advised for assessing the features of breast nodules. Breast nodules on ultrasound pictures are interpreted using the Breast Imaging, Reporting, and Data System (BIRADS) category, which has five features. Yet, the probability of a False Positive Result (FPR) on ultrasound imaging is relatively high. Computer Aided Diagnosis (CAD) was created to reduce FPR. However, CAD research based on many BIRADS traits is currently margined. As a result, based on three BIRADS characteristics, namely the margin, posterior, and orientation aspects, this study aims to proposed the methode for diagnosing breast nodule malignancy. The proposed method consists of 4 stages, namely, pre-processing, automatic segmentation, features extraction, and classification. Pre-processing adaptive median filter maximum window size is 11 pixels, linear histogram normalizing, and Reduction Anisotropic Diffusion (SRAD) filter were used to construct the method. The neutrosophic watershed method was used in the suggested automatic segmentation. Based on the nodule's margin, orientation, and posterior, 10 features were proposed: nodule width, gradient, slenderness, margin sharpness, shadow indicators, skewness, energy, entropy, dispersion, and solidity. MLP is a classification approach. The test used 94 nodule pictures and yielded an accuracy of 88.30%, a sensitivity of 82.35%, a specificity of 91.67%, a Kappa of 0.7449, and an AUC of 0.865. As a result, it is feasible to conclude that the proposed method is capable of detecting malignancy in breast nodules in ultrasound images. To make the proposed method more reliable in the future, automatic RoI can be developed.

Downloads

Download data is not yet available.

References

American Cancer Society, “Global Cancer Facts & Figures 3rd Edition.,” Atlanta, 2015. doi: 10.1002/ijc.27711.

Kementerian Kesehatan RI, “Jendela Data dan Inshapeasi Kesehatan,” Jakarta, pp. 1–44, 2015.

International Agency fot Research on Cancer, “Breast,” 2020. doi: 10.1016/B978-0-323-47912-7.00010-X.

American Cancer Society, “Breast Cancer Staging 7th Edition,” American Joint Committee on Cancer, pp. 1–2, 2010, [Online]. Available: cancerstaging.org

Globocan, “Cancer Incident in Indonesia,” International Agency for Research on Cancer, vol. 858, pp. 1–2, 2020, [Online]. Available: https://gco.iarc.fr/today/data/factsheets/populations/360-indonesia-fact-sheets.pdf

L. Levy, M. Suissa, J. F. Chiche, G. Teman, and B. Martin, “BIRADS ultrasonography,” EURR European Journal of Radiology, vol. 61, no. 2, pp. 202–211, 2007.

M. B. Mainiero et al., “ACR appropriateness criteria breast cancer screening,” Journal of the American College of Radiology, vol. 10, no. 1, pp. 11–14, 2013, doi: 10.1016/j.jacr.2012.09.036.

C. RA, “Computer aided detection (CAD): an overview.,” Cancer Imaging, vol. 5, pp. 17–19, 2005.

H. K. N. Yusufiyah, H. A. Nugroho, T. B. Adji, and A. Nugroho, “Feature Extraction for Classifying Lesion ’ s Shape of Breast Ultrasound Images,” The 2nd International Conference on Inshapeation Technology, Computer, and electrical Engineering, pp. 105–109, 2015.

H. A. Nugroho, Y. Triyani, M. Rahmawaty, and I. Ardiyanto, “Analysis of Margin Sharpness for Breast Nodule Classification on Ultrasound Images,” in International Conference on Inshapeation Technology and Electrical Engineering (ICITEE), 2017, no. Icitee. doi: 10.1109/ICITEED.2017.8250442.

M. Rahmawaty, H. A. Nugroho, Y. Triyani, I. Ardiyanto, and I. Soesanti, “Classification of breast ultrasound images based on texture analysis,” in 2016 1st International Conference on Biomedical Engineering (IBIOMED), 2016, pp. 84–89. doi: 10.1109/IBIOMED.2016.7869825.

H. A. Nugroho, Y. Triyani, M. Rahmawaty, and I. Ardiyanto, “Computer aided diagnosis using margin and posterior acoustic featuresfor breast ultrasound images,” Telkomnika (Telecommunication Computing Electronics and Control), vol. 15, no. 4, pp. 1776–1784, 2017, doi: 10.12928/TELKOMNIKA.v15i4.5021.

U. Erkan, S. Enginoğlu, D. N. H. Thanh, and L. M. Hieu, “Adaptive frequency median filter for the salt and pepper denoising problem,” IET Image Process, vol. 14, no. 7, 2020, doi: 10.1049/iet-ipr.2019.0398.

N. Mehta et al., “Repeatability of binarization thresholding methods for optical coherence tomography angiography image quantification,” Sci Rep, vol. 10, no. 1, 2020, doi: 10.1038/s41598-020-72358-z.

Y. Triyani and M. Rahmawaty, “Perbandingan Teknik Reduksi Derau Speckle Pada Citra Ultrasonograpi Payudara,” Elementer, vol. 4, no. 2, pp. 27–36, 2018, [Online]. Available: https://jurnal.pcr.ac.id/index.php/elementer/article/view/2409

Y. Yu and S. T. Acton, “Speckle reducing anisotropic diffusion,” IEEE Transaction on Image Processing, vol. 11, no. 11, pp. 1260–1270, 2002, doi: 10.1109/ICIP.2005.1529673.

A. Balodi, M. L. Dewal, and A. Rawat, “Comparison of despeckle filters for ultrasound images,” in (INDIACom), 2015 2nd International Conference on “Computing for Sustainable Global Development,” 2015, pp. 1919–1924.

C. P. Loizou and C. Pattichis, Despeckle Filtering for Ultrasound Imaging and Video Volume II : Selected Applications, Second., vol. II. Cyprus: Morgan & Claypool Publishers, 2015. doi: 10.2200/S00663ED1V01Y201508ASE015.

C. P. Loizou, C. S. Pattichis, C. I. Christodoulou, R. S. H. Istepanian, M. Pantziaris, and A. Nicolaides, “Comparative evaluation of despeckle filtering in ultrasound imaging of the carotid artery,” IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 52, no. 10. pp. 1653–1669, 2005. doi: 10.1109/TUFFC.2005.1561621.

H. A. Nugroho, Y. Triyani, M. Rahmawaty, and I. Ardiyanto, “Analysis of margin sharpness for breast nodule classification on ultrasound images,” in 2017 9th International Conference on Inshapeation Technology and Electrical Engineering (ICITEE), Oct. 2017, pp. 1–5. doi: 10.1109/ICITEED.2017.8250442.

Y. Triyani, H. A. Nugroho, M. Rahmawaty, I. Ardiyanto, and L. Choridah, “Pershapeance analysis of image segmentation for breast ultrasound images,” in 2016 8th International Conference on Inshapeation Technology and Electrical Engineering (ICITEE), 2016, pp. 1–6. doi: 10.1109/ICITEED.2016.7863298.

H. A. Nugroho, Y. Triyani, M. Rahmawaty, and I. Ardiyanto, “Breast ultrasound image segmentation based on neutrosophic set and watershed method for classifying margin characteristics,” in 2017 7th IEEE International Conference on System Engineering and Technology, ICSET 2017 - Proceedings, 2017. doi: 10.1109/ICSEngT.2017.8123418.

H. A. Nugroho, M. Rahmawaty, Y. Triyani, and I. Ardiyanto, “Neutrosophic and fuzzy C-means clustering for breast ultrasound image segmentation,” in 2017 9th International Conference on Inshapeation Technology and Electrical Engineering, ICITEE 2017, 2017, vol. 2018-Janua. doi: 10.1109/ICITEED.2017.8250453.

F. Zhu, J. Xu, M. Yang, and H. Chi, “Diffusion Tensor Imaging Features of Watershed Segmentation Algorithm for Analysis of the Relationship between Depression and Brain Nerve Function of Patients with End-Stage Renal Disease,” J Healthc Eng, vol. 2021, 2021, doi: 10.1155/2021/7036863.

A. A. Kasim, R. Wardoyo, and A. Harjoko, “Batik classification with artificial neural network based ontexture-shape feature of main ornament,” International Journal of Intelligent Systems and Applications, vol. 9, no. 6, 2017, doi: 10.5815/ijisa.2017.06.06.

M. Kumar, S. Gupta, X. Z. Gao, and A. Singh, “Plant Species Recognition Using Morphological Features and Adaptive Boosting Methodology,” IEEE Access, vol. 7, 2019, doi: 10.1109/ACCESS.2019.2952176.

M. Rahmawaty, H. A. Nugroho, Y. Triyani, I. Ardiyanto, and I. Soesanti, “Classification of breast ultrasound images based on texture analysis,” in Proceedings of 2016 1st International Conference on Biomedical Engineering: Empowering Biomedical Technology for Better Future, IBIOMED 2016, 2017. doi: 10.1109/IBIOMED.2016.7869825.